Environmental Simulation Capabilities

Environmental Simulation Capabilities

Our laboratory helps you deliver high performance, quality and robust products to any market by providing unique testing capabilities that ensure your products' durability and performance against extreme dynamic, climatic and environmental phenomena.

Environmental Simulation Capabilities

For additional information on these popular environmental simulation test sites, you can check out:

  • Flame Test
  • Drop Test
  • Ingress Protection Test
  • Shock and Vibration Test
  • Package Testing
  • Enclosure Test
  • Mushroom Test
  • Accelerated Stress Test
  • Competitive, Benchmarking and Fault Analysis
Acoustic Pressure (Sound Pressure
Level / Sound Power Level)
GR-63, GR-487; ETS 300 753; ISO 7779, ISO 3744;
EN 60945
Adhesive GR-326, GR-1081, GR-1221, GR-1073, GR-2883
Air Pollution GR-63, GR-487; ASTM B827; GR-326, GR-910,
GR-1222, GR-1081; EIA-364-65; ASTM B827
Altitude (up to 100.000 feet) GR-63; RTCA / DO-160 D, E & F, Section 4.0;
SAE J1455 MIL-STD-810, Method 500.4 by stream;
MIL-STD-202 F & G, Method 105C
Weakening GR-20, GR-326, GR-409, GR-487, GR-765,
GR-771, GR-910, GR-1222, TR-TSY-000949,
GR-950, GR-1081, GR-1209, GR-1221, GR-1073,
GR-2883, GR-1435, GR-2898; FOTP-107A, FOTP-20, FOTP-78, FOTP 30, FOTP-46, FOTP-50, FOTP-53
Strength of Plastics ASTM D953-02
Lead Resistance GR-487, GR-771, GR-950, GR-1081, GR-2898
Cable Aging GR-20, GR-409; FOTP-3
Connecting Cable GR-771, GR-950, GR-2898; TR-TSY-000949 XNUMX
Cable Core Blocking Capability GR-771, GR-950, GR-1081, GR-2898
Cable Freezing GR-20, GR-409; FOTP-3, FOTP-12
Cable Sheath Test GR-20, GR-326, GR-409, GR-1081; ASTM D1149,
ASTM D2444, ASTM D2794, ASTM D4565,
ASTM D518, ASTM D638, ASTM D1248,
ASTM D1603, ASTM D3349, ASTM D3895;
FOTP-89, FOTP-86;
Cable Materials Test GR-20, GR-326, GR-409, GR-1081; ASTM D1149,
ASTM D1248, ASTM D1603
ASTM D1693, ASTM D3349, ASTM D3895, ASTM D3418-82;
FOTP-12, FOTP-81
Cable termination GR-20, GR-409

Central Member Logout

GR-771, GR-950, GR-1081, GR-2898
Chemical / Liquid Compatibility MIL-STD-810, Method 504 for Current;
RTCA / DO-160D, E & F, Section 11.0;
NEMA 250; EN 60945; GR-487; SAE J1455
Chemical Sequences GR-765, GR-771, TR-TSY-000949, GR-950, GR-1081,
GR-2898
Component Effect GR-1209; FOTP-2; ANSI B109.1, 2 and 4
Compression test GR-20, GR-409, GR-765, GR-771, TR-TSY-000949,
GR-950, GR-1081, GR-2898; FOTP-41
Metallic Materials
Compression Test at Room Temperature (cylindrical samples only)
ASTM E9-89a (Reconfirmed 2000)
Pressure Properties of Rigid Plastics ASTM D695
Connector Installation GR-326, GR-1081
Contact Bounce MIL-STD-202 F & G, Method 310 (
Measured with an oscilloscope)
Corrosion Resistance - Salt Fog Spray GR-326, GR-487, GR-771, GR-950, GR-1081,
GR-2898; FOTP-16; ASTM B117, ASTM D610;
IEC 60068 2 52
Corrosion Resistance Acid Salt Water GR-771, GR-1081, GR-2898; ASTM D610; FOTP-12

Creep, Creep-Rupture and Stress-Rupture Tests of Metallic Materials
ASTM E139-06 standard
Drop / Shock Tests (Free Fall) ASTM D5276; IEC 60068-2-32; EN 60945;
SAE J1455; GR-63, GR-487, GR-326, GR-765,
GR-771, GR-910, GR-1222, GR-950, GR-1081,
GR-2898; ETS 300-019-2-1 to 8;
MIL-STD-810 - current, Method 516.5 (IV and VI)
Drying Step GR-326, GR-1081, FOTP-3, ASTM E145
durability GR-326, GR-910, GR-1222, GR-1081, GR-1435;
FOTP-21
Dust Test GR-487, GR-326, GR-771, GR-950, GR-1081,
GR-1435, GR-2898; FOTP-35
Dust Test (Blowing) MIL-STD-810, Method 510, Procedure I;
ANSI/EIA/TIA 455-35 (FOTP-35);
IEC 60068-2-68, Method Lc1, Variant 2
Dust Test (Housing) IEC 60529, IP5x and 6x;
IEC 60068-2-68, Method La2;
ISO 20653, IP5K and 6K
Dust Test GR-487, GR-326, GR-771,
Earthquake Resistance / Seismic
Hydraulic: Sine / Random / Earthquake
Seismic: (1 - 500) Hz; Up to 40.000 lbs-power;
Load up to 6.000 lbs
GR-487, GR-63; ETS 300-019-2-3, ETS 300-019-2-4
Enclosure Integrity NEMA 250; IEC 60529-2001; ISO 20653; EN 60945
End Face Geometry Measurement GR-326, GR-1081; FOTP-55, FOTP 57, FOTP 179
Environmental Vibration GR-487; FOTP-11; MIL-STD-810E
patlama RTCA / DO-160 Categories A, E
Fiber and Cable Gripping (Straight Pull) GR-20, GR-326, GR-409, GR-910, GR-1222,
GR-1081, GR-1209, GR-1221, GR-1073, GR-2883;
ASTM D638; FOTP-33, FOTP-6, FOTP-89
Fiber Stretch GR-20, GR-326, GR-409, GR-487, GR-765, GR-771,
GR-910, GR-1222, TR-TSY-000949, GR-950,
GR-1081, GR-1209, GR-1221, GR-1073, GR-2883,
GR-1435, GR-2898; FOTP-1, FOTP-33, FOTP 104
Fire Resistance GR-326, GR-409, GR-487, GR-771, TR-TSY-000949,
GR-950, GR-1081, GR-2898; ASTM D2863,
ASTM D56, ASTM E119
Flame Spread and Analysis (Electric
Products and Components)
GR-63; ANSI T1.319-2002;
Verizon VZ TPR 9305
Flood protection TR-TSY-000949 XNUMX
Liquid Immersion GR-771, GR-910, GR-1222, TR-TSY-000949,
GR-950, GR-1209, GR-2898; FOTP-12; IEC 60529;
ISO 20653; EN 60945; SAE J1455
Mushroom Resistance ASTM G21; ISO 846; SAE J1455;
MIL-STD-810 - Current, Method 508.5;
RTCA / DO-160D, E & F, Section 13.0;
GR-20, GR-326, GR-409, GR-487, GR-765, GR-771,
TR-TSY-000949, GR-950, GR-1081, GR-2898;
IEC 60068-2-10 (part 2-10, test J)
Gaseous Contaminants / Corrosion ASTM B810, ASTM B827, ASTM G85;
EIA-364-65; ISO 9227; NEMA 250;
UL 1332-1995, 3rd Edition, Sec. 8; GR-63, GR-487
Groundwater Immersion GR-326, GR-1081; FOTP-12
High / Low Temperature GR-63, GR-950, GR-487;
RTCA / DO-160 D, E & F, Sections 4.0 and 5.0;
EN 60945; SAE J1455; NEMA 250;
MIL-STD-810 - Current, Methods 501.4 and 502.4;
MIL-STD-202 F & G, Method 108A;
MIL-STD-883 E & F, Method 1010.7;
IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-14;
ETS 300-019-2-1 to -8;
ASTM E145; GR-20, GR-326, GR-409, GR-487,
GR-765, GR-771, GR-910, GR-1222,
GR-950, GR-1081, GR-1209, GR-1221, GR-1073,
GR-2883, GR-1435, GR-2898; FOTP-3, FOTP-4,
FOTP-98; ANSI B109.1, 2, 4; ANSI C12.1, C12.20;
TR-TSY-000949 XNUMX
Humidity (Moisture Resistance) / Humidity
Aging
GR-63, GR-487, GR-950; EN 60945; SAE J1455;
GR-1221, GR-1073, GR-2883;
RTCA / DO-160D, E & F Sec 6.0;
MIL-STD-810 - Current, Method 507.4;
MIL-STD-202 F & G, Method 103B and 106G;
MIL-STD-883 E and F;
IEC 60068-2-30; IEC 60068-2-56;
ETS 300-019-2-1 to 8;
GR-20, GR-326, GR-409, GR-487, GR-765, GR-771,
GR-910, GR-1222, TR-TSY-000949, GR-950, GR-
1081, GR-1209, GR-1221, GR-1073, GR-2883,
GR-1435, GR-2898; FOTP-3; ANSI C12.1, C12.20;
ASTM E45; FOTP-5B
Moisture and Condensation Cycle Test GR-20, GR-326, GR-409, GR-487, GR-765,
GR-771, GR-910, GR-1222, TR-TSY-000949,
GR-950, GR-1081, GR-1209, GR-1221, GR-1073,
GR-2883, GR-1435, GR-2898; FOTP-3;
ASTM E145; FOTP-5B
ice cap NEMA 250;
MIL-STD-810, Method 521.2;
RTCA / DO 160 D&E, Seconds 24.0
Lighting GR-63
dip MIL-STD-202 F & G, Method 104A;
MIL-STD-810 - Current, Method 512.4;
GR-49, GR-950; EN 60945; SAE J1455
Immersion / Corrosion GR-326, GR-1081, FOTP-12
Insect Resistance GR-950, GR-1081; GR-487
Insertion Loss GR-20, GR-326, GR-409, GR-487, GR-765, GR-771,
GR-910, GR-1222, TR-TSY-000949, GR-950, GR1081,
GR-1209, GR-1221, GR-1073, GR-2883, GR-1435,
GR-2898; FOTP-107A, FOTP-20, FOTP-78, FOTP 170
Installation Shock GR-487; MIL-STD-810E
Lawn Sprinklers GR-487
Mechanical Effect GR-326, GR-487, GR-771, GR-910, GR-1222,
TR-TSY-000949, GR-950, GR-1081, GR-1221,
GR-1073, GR-2883, GR-1435, GR-2898; FOTP-2,
FOTP-25
Mechanical Shock
Avco: up to 30.000 g half sine / saw tooth Electrodynamics: half sine / saw
female / triangle /
rectangular / trapizoid / haversine / temporal (SRS)
Up to 18.000 lbs-force
Hydraulics: Half sine up to 40.000 lbs-force; until
6,000 lb load; Up to 20 g
GR-326, GR-487, GR-63, GR-765, GR-910,
GR-1222, GR-1081, GR-1209, GR-1221, GR-1073,
GR-2883, GR-1435; FOTP-2a; MIL-STD-810,
MIL-STD-202, MIL-STD-883; IEC 60068-2-27,
IEC 60068-2-29; RTCA/DO160; SAE J1455;
ETS 300-019-2-1 - 8
Mechanical Vibration
Sine / Random / Gunfire / Sine Random / Random
Random / sine and
Random Random: (5 to 3000) Hz
, 9.000 lbs-force
GR-326, GR-910, GR-1222, GR-1081, GR-1209,
GR-1221, GR-1073, GR-2883, GR-1435, GR-63,
GR-487, GR-765, GR-1081; FOTP-11;
MIL-STD-810, MIL-STD-202 F & G,
MIL-STD-883 E & F;
RTCA / DO-160 D, E & F, Section 8.0;
EN 60945; SAE J1455;
MIL-STD-202 F & G, Methods 201, 204 and 214;
MIL-STD-167-1 and 167-1A, Type 1;
ASTM D3580; ASTM D4728; IEC 60068-2-6;
IEC 60068-2-36; IEC 60721-3-4;
ETS 300-019-2-1 - 8
Module Effect GR-1209; FOTP-2
Package / Shipping Test ASTM D4169; 49 C.F.R. 178
Loss Due to Polarization (PDL) GR-910, GR-1222, GR-1209, FOTP-122, FOTP-124
Polarization Mode Distribution (PMD) GR-910, GR-1222, GR-1209; FOTP-113
Projection GR-326, GR-910, GR-1222, GR-1081; FOTP-107a,
FOTP-20
Organic Coatings
Resistance to the Effects of Rapid Deformation (Impact)
ASTM D2794
Rockwell Hardness Test GR-771, GR-950, GR-1081, GR-2898; ASTM D785
Salt Spray GR-487; RTCA / DO-160 D, E & F, Section 14.0;
GR-950; ISO 21207, ISO 9227; EN 60945;
SAE J1455; ASTM G85, ASTM B117;
MIL-STD-810 - Current, Method 509.4;
MIL-STD-202 F & G, Method 101E;
NEMA 250; UL 1332-1995, 3rd Edition, Sec. 7;
ANSI B109.1, 2 and 3
Shear Strength of Plastic with Punch Tool ASTM D732
Sheath Keeping GR-326, GR-771, GR-910, GR-1222, TR-TSY-000949, GR-950, GR-1081, GR-2898; FOTP-6
Side Pull GR-326, GR-910, GR-1222, GR-1081, GR-1209,
GR-1221, GR-1073, GR-2883, GR-1435; ASTM D638;
FOTP-33, FOTP-6, FOTP-89
Solar radiation MIL-STD-810 - Current, Method 505.4;
GR-487; IEC 60068-2-5; DIN 75220
ASTM G155; EN 60079-0, Clause 26.10, EN 60945
Steam Cleaning and Pressure Washing SAE J1455
Temperature Cycle ASTM E145; GR-20, GR-326, GR-409, GR-487,
GR-765, GR-771, GR-910, GR-1222,
TR-TSY-000949, GR-950, GR-1081, GR-1209,
GR-1221, GR-1073, GR-2883, GR-1435, GR-2898;
FOTP-3, FOTP-4; MIL-STD-810E; SAE J1455

Tensile Testing up to 2000 lbsF
GR-20, GR-326, GR-409, GR-487, GR-765, GR-771,
GR-910, GR-1222, TR-TSY-000949, GR-950, GR1081,
GR-1209, GR-1221, GR-1073, GR-2883, GR-1435,
GR-2898; ASTM E8, ASTM D638, ASTM E8,
ASTM E8M; FOTP-33, FOTP-89, FOTP-38, FOTP-28

Tensile, Compression and Bending, Creep and Creep-Break of Plastics
ATSM D 2990-01
Stuffed Toys and
Tensile Test for Stitches in Beanbag Type Toys
ASTM F 963-03 (Section 8.9.1)
Pulling / Pressing GR-950; NEMA 250
Thermal shock GR-63, GR-326, GR-487, GR-910, GR-1222,
GR-1081, GR-1221, GR-1073, GR-2883; FOTP-3;
ASTM D3332; ASTM E145; FOTP-4, FOTP-71,
FOTP-98; MIL-STD-202; MIL-STD-810;
MIL-STD-883; EN 60945; SAE J1455;
ANSI B109.1, 2, 4
Transmission with Applied Tensile Load GR-326, GR-1081; FOTP-33
Transparent Armor ATPD2352D 3.2.8 / 4.2.4 (marking),
3.2.9 / 4.2.5 (tolerance), 3.3.7 / 4.3.7.2 (chemical),
3.2.6 / 4.2.6 (defrosting),
3.3.1.1 /4.3.1.1 (low temperature),
3.3.1.2/4.3.1.2 (high temperature),
3.3.2 / 4.3.2 (humidity)
3.3.4 / 4.3.4 (temperature shock),
3.3.5 / 4.3. 5 (sun exposure decomposition)
Bending / Torsion Test GR-20, GR-326, GR-409, GR-771, GR-910, GR-1222,
TR-TSY-000949, GR-950, GR-1081, GR-1209,
GR-1221, GR-1073, GR-2883, GR-2898; FOTP-36,
FOTP-85
UV Exposure ASTM G153, ASTM G154, ASTM G155; GR-326,
GR-487, GR-765, GR-771, GR-910, TR-TSY-000949,
GR-950, GR-1222, GR-2898;
EN 60079-0 Clause 26.10;
UL 746C Sections 25 and 27; UL 969 Section 7.1.6B;
IEC 62093 Section 11.10; IEC 61215 Section 10.10;
IEC 61646 Section 10.10; CO / PD 04-19
Visual Inspection and Dimensions GR-20, GR-326, GR-409, GR-487, GR-765, GR-771,
GR-910, GR-1222, TR-TSY-000949, GR-950,
GR-1081, GR-1209, GR-1221, GR-1073, GR-2883,
GR-1435, GR-2898; FOTP-13, FOTP-48; FOTP-123,
FOTP-173 FOTP-179; ASTM E29
Water penetration GR-20, GR-409; FOTP-82
Sealing / Rain GR-487; RTCA / DO-160 D, E & F, Section 10.0;
MIL-STD-108E,
MIL-STD-810, Method 506.4 for Current;
IEC 60529, ISO 20653; NEMA 250; EN 60945;
IEC 60068-2-18; ETS 300-019-2-1 to -8;
Wind Driven Rain MIL-STD-810, Method 506.4; GR-487, GR-771
Window Opening Test ANSI B109.1, 2 and 3

EUROLAB, with its highly expert team and internationally accredited laboratories, Environmental Simulation Capabilities It performs all test, analysis, measurement, evaluation and report generation services completely and reliably.

WhatsApp