Our laboratory helps you deliver high performance, quality and robust products to any market by providing unique testing capabilities that ensure your products' durability and performance against extreme dynamic, climatic and environmental phenomena.

For additional information on these popular environmental simulation test sites, you can check out:
| Acoustic Pressure (Sound Pressure Level / Sound Power Level) |
GR-63, GR-487; ETS 300 753; ISO 7779, ISO 3744; EN 60945 |
| Adhesive | GR-326, GR-1081, GR-1221, GR-1073, GR-2883 |
| Air Pollution | GR-63, GR-487; ASTM B827; GR-326, GR-910, GR-1222, GR-1081; EIA-364-65; ASTM B827 |
| Altitude (up to 100.000 feet) | GR-63; RTCA / DO-160 D, E & F, Section 4.0; SAE J1455 MIL-STD-810, Method 500.4 by stream; MIL-STD-202 F & G, Method 105C |
| Weakening | GR-20, GR-326, GR-409, GR-487, GR-765, GR-771, GR-910, GR-1222, TR-TSY-000949, GR-950, GR-1081, GR-1209, GR-1221, GR-1073, GR-2883, GR-1435, GR-2898; FOTP-107A, FOTP-20, FOTP-78, FOTP 30, FOTP-46, FOTP-50, FOTP-53 |
| Strength of Plastics | ASTM D953-02 |
| Lead Resistance | GR-487, GR-771, GR-950, GR-1081, GR-2898 |
| Cable Aging | GR-20, GR-409; FOTP-3 |
| Connecting Cable | GR-771, GR-950, GR-2898; TR-TSY-000949 XNUMX |
| Cable Core Blocking Capability | GR-771, GR-950, GR-1081, GR-2898 |
| Cable Freezing | GR-20, GR-409; FOTP-3, FOTP-12 |
| Cable Sheath Test | GR-20, GR-326, GR-409, GR-1081; ASTM D1149, ASTM D2444, ASTM D2794, ASTM D4565, ASTM D518, ASTM D638, ASTM D1248, ASTM D1603, ASTM D3349, ASTM D3895; FOTP-89, FOTP-86; |
| Cable Materials Test | GR-20, GR-326, GR-409, GR-1081; ASTM D1149, ASTM D1248, ASTM D1603 ASTM D1693, ASTM D3349, ASTM D3895, ASTM D3418-82; FOTP-12, FOTP-81 |
| Cable termination | GR-20, GR-409 |
|
Central Member Logout |
GR-771, GR-950, GR-1081, GR-2898 |
| Chemical / Liquid Compatibility | MIL-STD-810, Method 504 for Current; RTCA / DO-160D, E & F, Section 11.0; NEMA 250; EN 60945; GR-487; SAE J1455 |
| Chemical Sequences | GR-765, GR-771, TR-TSY-000949, GR-950, GR-1081, GR-2898 |
| Component Effect | GR-1209; FOTP-2; ANSI B109.1, 2 and 4 |
| Compression test | GR-20, GR-409, GR-765, GR-771, TR-TSY-000949, GR-950, GR-1081, GR-2898; FOTP-41 |
| Metallic Materials Compression Test at Room Temperature (cylindrical samples only) |
ASTM E9-89a (Reconfirmed 2000) |
| Pressure Properties of Rigid Plastics | ASTM D695 |
| Connector Installation | GR-326, GR-1081 |
| Contact Bounce | MIL-STD-202 F & G, Method 310 ( Measured with an oscilloscope) |
| Corrosion Resistance - Salt Fog Spray | GR-326, GR-487, GR-771, GR-950, GR-1081, GR-2898; FOTP-16; ASTM B117, ASTM D610; IEC 60068 2 52 |
| Corrosion Resistance Acid Salt Water | GR-771, GR-1081, GR-2898; ASTM D610; FOTP-12 |
Creep, Creep-Rupture and Stress-Rupture Tests of Metallic Materials |
ASTM E139-06 standard |
| Drop / Shock Tests (Free Fall) | ASTM D5276; IEC 60068-2-32; EN 60945; SAE J1455; GR-63, GR-487, GR-326, GR-765, GR-771, GR-910, GR-1222, GR-950, GR-1081, GR-2898; ETS 300-019-2-1 to 8; MIL-STD-810 - current, Method 516.5 (IV and VI) |
| Drying Step | GR-326, GR-1081, FOTP-3, ASTM E145 |
| durability | GR-326, GR-910, GR-1222, GR-1081, GR-1435; FOTP-21 |
| Dust Test | GR-487, GR-326, GR-771, GR-950, GR-1081, GR-1435, GR-2898; FOTP-35 |
| Dust Test (Blowing) | MIL-STD-810, Method 510, Procedure I; ANSI/EIA/TIA 455-35 (FOTP-35); IEC 60068-2-68, Method Lc1, Variant 2 |
| Dust Test (Housing) | IEC 60529, IP5x and 6x; IEC 60068-2-68, Method La2; ISO 20653, IP5K and 6K Dust Test GR-487, GR-326, GR-771, |
| Earthquake Resistance / Seismic Hydraulic: Sine / Random / Earthquake Seismic: (1 - 500) Hz; Up to 40.000 lbs-power; Load up to 6.000 lbs |
GR-487, GR-63; ETS 300-019-2-3, ETS 300-019-2-4 |
| Enclosure Integrity | NEMA 250; IEC 60529-2001; ISO 20653; EN 60945 |
| End Face Geometry Measurement | GR-326, GR-1081; FOTP-55, FOTP 57, FOTP 179 |
| Environmental Vibration | GR-487; FOTP-11; MIL-STD-810E |
| patlama | RTCA / DO-160 Categories A, E |
| Fiber and Cable Gripping (Straight Pull) | GR-20, GR-326, GR-409, GR-910, GR-1222, GR-1081, GR-1209, GR-1221, GR-1073, GR-2883; ASTM D638; FOTP-33, FOTP-6, FOTP-89 |
| Fiber Stretch | GR-20, GR-326, GR-409, GR-487, GR-765, GR-771, GR-910, GR-1222, TR-TSY-000949, GR-950, GR-1081, GR-1209, GR-1221, GR-1073, GR-2883, GR-1435, GR-2898; FOTP-1, FOTP-33, FOTP 104 |
| Fire Resistance | GR-326, GR-409, GR-487, GR-771, TR-TSY-000949, GR-950, GR-1081, GR-2898; ASTM D2863, ASTM D56, ASTM E119 |
| Flame Spread and Analysis (Electric Products and Components) |
GR-63; ANSI T1.319-2002; Verizon VZ TPR 9305 |
| Flood protection | TR-TSY-000949 XNUMX |
| Liquid Immersion | GR-771, GR-910, GR-1222, TR-TSY-000949, GR-950, GR-1209, GR-2898; FOTP-12; IEC 60529; ISO 20653; EN 60945; SAE J1455 |
| Mushroom Resistance | ASTM G21; ISO 846; SAE J1455; MIL-STD-810 - Current, Method 508.5; RTCA / DO-160D, E & F, Section 13.0; GR-20, GR-326, GR-409, GR-487, GR-765, GR-771, TR-TSY-000949, GR-950, GR-1081, GR-2898; IEC 60068-2-10 (part 2-10, test J) |
| Gaseous Contaminants / Corrosion | ASTM B810, ASTM B827, ASTM G85; EIA-364-65; ISO 9227; NEMA 250; UL 1332-1995, 3rd Edition, Sec. 8; GR-63, GR-487 |
| Groundwater Immersion | GR-326, GR-1081; FOTP-12 |
| High / Low Temperature | GR-63, GR-950, GR-487; RTCA / DO-160 D, E & F, Sections 4.0 and 5.0; EN 60945; SAE J1455; NEMA 250; MIL-STD-810 - Current, Methods 501.4 and 502.4; MIL-STD-202 F & G, Method 108A; MIL-STD-883 E & F, Method 1010.7; IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-14; ETS 300-019-2-1 to -8; ASTM E145; GR-20, GR-326, GR-409, GR-487, GR-765, GR-771, GR-910, GR-1222, GR-950, GR-1081, GR-1209, GR-1221, GR-1073, GR-2883, GR-1435, GR-2898; FOTP-3, FOTP-4, FOTP-98; ANSI B109.1, 2, 4; ANSI C12.1, C12.20; TR-TSY-000949 XNUMX |
| Humidity (Moisture Resistance) / Humidity Aging |
GR-63, GR-487, GR-950; EN 60945; SAE J1455; GR-1221, GR-1073, GR-2883; RTCA / DO-160D, E & F Sec 6.0; MIL-STD-810 - Current, Method 507.4; MIL-STD-202 F & G, Method 103B and 106G; MIL-STD-883 E and F; IEC 60068-2-30; IEC 60068-2-56; ETS 300-019-2-1 to 8; GR-20, GR-326, GR-409, GR-487, GR-765, GR-771, GR-910, GR-1222, TR-TSY-000949, GR-950, GR- 1081, GR-1209, GR-1221, GR-1073, GR-2883, GR-1435, GR-2898; FOTP-3; ANSI C12.1, C12.20; ASTM E45; FOTP-5B |
| Moisture and Condensation Cycle Test | GR-20, GR-326, GR-409, GR-487, GR-765, GR-771, GR-910, GR-1222, TR-TSY-000949, GR-950, GR-1081, GR-1209, GR-1221, GR-1073, GR-2883, GR-1435, GR-2898; FOTP-3; ASTM E145; FOTP-5B |
| ice cap | NEMA 250; MIL-STD-810, Method 521.2; RTCA / DO 160 D&E, Seconds 24.0 |
| Lighting | GR-63 |
| dip | MIL-STD-202 F & G, Method 104A; MIL-STD-810 - Current, Method 512.4; GR-49, GR-950; EN 60945; SAE J1455 |
| Immersion / Corrosion | GR-326, GR-1081, FOTP-12 |
| Insect Resistance | GR-950, GR-1081; GR-487 |
| Insertion Loss | GR-20, GR-326, GR-409, GR-487, GR-765, GR-771, GR-910, GR-1222, TR-TSY-000949, GR-950, GR1081, GR-1209, GR-1221, GR-1073, GR-2883, GR-1435, GR-2898; FOTP-107A, FOTP-20, FOTP-78, FOTP 170 |
| Installation Shock | GR-487; MIL-STD-810E |
| Lawn Sprinklers | GR-487 |
| Mechanical Effect | GR-326, GR-487, GR-771, GR-910, GR-1222, TR-TSY-000949, GR-950, GR-1081, GR-1221, GR-1073, GR-2883, GR-1435, GR-2898; FOTP-2, FOTP-25 |
| Mechanical Shock Avco: up to 30.000 g half sine / saw tooth Electrodynamics: half sine / saw female / triangle / rectangular / trapizoid / haversine / temporal (SRS) Up to 18.000 lbs-force Hydraulics: Half sine up to 40.000 lbs-force; until 6,000 lb load; Up to 20 g |
GR-326, GR-487, GR-63, GR-765, GR-910, GR-1222, GR-1081, GR-1209, GR-1221, GR-1073, GR-2883, GR-1435; FOTP-2a; MIL-STD-810, MIL-STD-202, MIL-STD-883; IEC 60068-2-27, IEC 60068-2-29; RTCA/DO160; SAE J1455; ETS 300-019-2-1 - 8 |
| Mechanical Vibration Sine / Random / Gunfire / Sine Random / Random Random / sine and Random Random: (5 to 3000) Hz , 9.000 lbs-force |
GR-326, GR-910, GR-1222, GR-1081, GR-1209, GR-1221, GR-1073, GR-2883, GR-1435, GR-63, GR-487, GR-765, GR-1081; FOTP-11; MIL-STD-810, MIL-STD-202 F & G, MIL-STD-883 E & F; RTCA / DO-160 D, E & F, Section 8.0; EN 60945; SAE J1455; MIL-STD-202 F & G, Methods 201, 204 and 214; MIL-STD-167-1 and 167-1A, Type 1; ASTM D3580; ASTM D4728; IEC 60068-2-6; IEC 60068-2-36; IEC 60721-3-4; ETS 300-019-2-1 - 8 |
| Module Effect | GR-1209; FOTP-2 |
| Package / Shipping Test | ASTM D4169; 49 C.F.R. 178 |
| Loss Due to Polarization (PDL) | GR-910, GR-1222, GR-1209, FOTP-122, FOTP-124 |
| Polarization Mode Distribution (PMD) | GR-910, GR-1222, GR-1209; FOTP-113 |
| Projection | GR-326, GR-910, GR-1222, GR-1081; FOTP-107a, FOTP-20 |
| Organic Coatings Resistance to the Effects of Rapid Deformation (Impact) |
ASTM D2794 |
| Rockwell Hardness Test | GR-771, GR-950, GR-1081, GR-2898; ASTM D785 |
| Salt Spray | GR-487; RTCA / DO-160 D, E & F, Section 14.0; GR-950; ISO 21207, ISO 9227; EN 60945; SAE J1455; ASTM G85, ASTM B117; MIL-STD-810 - Current, Method 509.4; MIL-STD-202 F & G, Method 101E; NEMA 250; UL 1332-1995, 3rd Edition, Sec. 7; ANSI B109.1, 2 and 3 |
| Shear Strength of Plastic with Punch Tool | ASTM D732 |
| Sheath Keeping | GR-326, GR-771, GR-910, GR-1222, TR-TSY-000949, GR-950, GR-1081, GR-2898; FOTP-6 |
| Side Pull | GR-326, GR-910, GR-1222, GR-1081, GR-1209, GR-1221, GR-1073, GR-2883, GR-1435; ASTM D638; FOTP-33, FOTP-6, FOTP-89 |
| Solar radiation | MIL-STD-810 - Current, Method 505.4; GR-487; IEC 60068-2-5; DIN 75220 ASTM G155; EN 60079-0, Clause 26.10, EN 60945 |
| Steam Cleaning and Pressure Washing | SAE J1455 |
| Temperature Cycle | ASTM E145; GR-20, GR-326, GR-409, GR-487, GR-765, GR-771, GR-910, GR-1222, TR-TSY-000949, GR-950, GR-1081, GR-1209, GR-1221, GR-1073, GR-2883, GR-1435, GR-2898; FOTP-3, FOTP-4; MIL-STD-810E; SAE J1455 |
Tensile Testing up to 2000 lbsF |
GR-20, GR-326, GR-409, GR-487, GR-765, GR-771, GR-910, GR-1222, TR-TSY-000949, GR-950, GR1081, GR-1209, GR-1221, GR-1073, GR-2883, GR-1435, GR-2898; ASTM E8, ASTM D638, ASTM E8, ASTM E8M; FOTP-33, FOTP-89, FOTP-38, FOTP-28 |
Tensile, Compression and Bending, Creep and Creep-Break of Plastics |
ATSM D 2990-01 |
| Stuffed Toys and Tensile Test for Stitches in Beanbag Type Toys |
ASTM F 963-03 (Section 8.9.1) |
| Pulling / Pressing | GR-950; NEMA 250 |
| Thermal shock | GR-63, GR-326, GR-487, GR-910, GR-1222, GR-1081, GR-1221, GR-1073, GR-2883; FOTP-3; ASTM D3332; ASTM E145; FOTP-4, FOTP-71, FOTP-98; MIL-STD-202; MIL-STD-810; MIL-STD-883; EN 60945; SAE J1455; ANSI B109.1, 2, 4 |
| Transmission with Applied Tensile Load | GR-326, GR-1081; FOTP-33 |
| Transparent Armor | ATPD2352D 3.2.8 / 4.2.4 (marking), 3.2.9 / 4.2.5 (tolerance), 3.3.7 / 4.3.7.2 (chemical), 3.2.6 / 4.2.6 (defrosting), 3.3.1.1 /4.3.1.1 (low temperature), 3.3.1.2/4.3.1.2 (high temperature), 3.3.2 / 4.3.2 (humidity) 3.3.4 / 4.3.4 (temperature shock), 3.3.5 / 4.3. 5 (sun exposure decomposition) |
| Bending / Torsion Test | GR-20, GR-326, GR-409, GR-771, GR-910, GR-1222, TR-TSY-000949, GR-950, GR-1081, GR-1209, GR-1221, GR-1073, GR-2883, GR-2898; FOTP-36, FOTP-85 |
| UV Exposure | ASTM G153, ASTM G154, ASTM G155; GR-326, GR-487, GR-765, GR-771, GR-910, TR-TSY-000949, GR-950, GR-1222, GR-2898; EN 60079-0 Clause 26.10; UL 746C Sections 25 and 27; UL 969 Section 7.1.6B; IEC 62093 Section 11.10; IEC 61215 Section 10.10; IEC 61646 Section 10.10; CO / PD 04-19 |
| Visual Inspection and Dimensions | GR-20, GR-326, GR-409, GR-487, GR-765, GR-771, GR-910, GR-1222, TR-TSY-000949, GR-950, GR-1081, GR-1209, GR-1221, GR-1073, GR-2883, GR-1435, GR-2898; FOTP-13, FOTP-48; FOTP-123, FOTP-173 FOTP-179; ASTM E29 |
| Water penetration | GR-20, GR-409; FOTP-82 |
| Sealing / Rain | GR-487; RTCA / DO-160 D, E & F, Section 10.0; MIL-STD-108E, MIL-STD-810, Method 506.4 for Current; IEC 60529, ISO 20653; NEMA 250; EN 60945; IEC 60068-2-18; ETS 300-019-2-1 to -8; |
| Wind Driven Rain | MIL-STD-810, Method 506.4; GR-487, GR-771 |
| Window Opening Test | ANSI B109.1, 2 and 3 |
EUROLAB, with its highly expert team and internationally accredited laboratories, Environmental Simulation Capabilities It performs all test, analysis, measurement, evaluation and report generation services completely and reliably.