The standard "VDI 6022-1 Hygienic standards for ventilation and air conditioning systems - Part 1: Offices and meeting rooms" published by the Association of German Engineers (VDI) describes the requirements for hygiene in air conditioning systems and equipment in order to adjust the air without creating any negative effects. This standard includes the principles for the design, construction and operation of air conditioning units and air conditioning unit equipment and their components.

This standard relates to hygiene in heating, ventilation and air conditioning (HVAC) systems with the aim of preventing adverse effects on room air. The VDI 6022-1 standard lists integrated hygiene requirements regarding the structural, technical and organizational effects on the planning, construction, operation and maintenance of HVAC systems. It also serves as a basis for testing during a hygiene audit. These requirements primarily serve to protect the health of individuals.
Until now, geothermal heat exchangers have been excluded because the temperature must remain above the dew point. The latest update of this standard also describes how hygiene can be ensured in HVAC systems with underground air pipes. In addition, sections have been added to the standard to introduce air measurement, explain risk assessment and set filter classes.
The VDI 6022-1 standard provides guidelines for the practical assessment of the cleanliness of HVAC systems. The measurement methods preferred by European standards are evaluated according to this standard with respect to existing measurement methods.
Many modern infrastructures, such as meeting places, restaurants, underground car parks and office buildings, require hygiene inspections according to the VDI 6022 standard. This is very important because inadequate hygiene in HVAC systems creates ideal breeding grounds for microorganisms and causes irritation of the mucous membranes, headaches, lack of concentration, asthma, allergies and even infections.
Current legal regulations demand that HVAC systems be planned and operated in a way that prevents any health hazards or adverse effects on the well-being of users. The relevant requirements are specified in various guidelines and standards, in particular the VDI 6022 standard.
Ensuring that indoor environments are supplied with clean, fresh air is essential to ensure a healthy and comfortable atmosphere for the occupants. The VDI 6022 hygiene standard plays a vital role in achieving this goal and takes into account the cleanliness of HVAC units and associated ductwork.
In the early 1980s, the World Health Organization (WHO) reported that approximately 30 percent of newly constructed or renovated buildings had serious indoor air quality problems. The first version of the VDI 6022 standard was published in the late 1990s. This standard is used to set criteria for hygiene requirements and methods for assessing indoor air quality for indoor ventilation and air conditioning systems.
The VDI 6022 standard is a German standard that is mandatory for commercially developed real estate such as office buildings, administrative buildings, production facilities, schools or hotels, but has also achieved a high level of recognition in other European countries.
The primary reason why this standard is so important for ventilation solutions is its impact on health. Proper ventilation is critical to reducing the concentration of harmful substances, pollutants, and airborne pathogens in indoor spaces. Compliance with this standard helps reduce the risk of indoor air pollution, respiratory problems, and airborne infections.
Among the numerous tests, measurements, analyses and evaluations our organization has carried out for businesses in various sectors, our organization also provides testing services defined in the standard “VDI 6022-1 Hygienic standards for ventilation and air conditioning systems - Part 1: Offices and meeting rooms” with its trained and expert staff and advanced technological equipment.