The standard "ISO 16900-1 Respiratory protective devices - Test methods and test equipment - Part 1: Determination of inward leakage" published by the International Organization for Standardization (ISO) describes test methods to determine the inward leakage of respiratory interfaces and the total inward leakage of complete respiratory protective devices at specified metabolic work rates, using specified test agents and incorporating specified body movements. These tests are performed in laboratories using specified test agents under specified conditions and therefore do not represent the performance of the device in actual use.

For the purposes of this standard, in addition to the terms and definitions given in ISO 16972 Respiratory protective devices - Vocabulary and graphical symbols, the following definitions apply:
Performance standards should specify test conditions. Prerequisites described in this standard include:
Unless otherwise stated, values stated in this standard are expressed as nominal values. Values not stated as maximum or minimum, except for temperature limits, are subject to a tolerance of plus/minus 5 percent. Unless otherwise stated, ambient conditions for testing shall be between 16 degrees and 32 degrees and 50 percent plus/minus 30 percent relative humidity. Any temperature limits stated are subject to accuracy of plus/minus 1 degree.
For each of the required measurements performed in accordance with this standard, a corresponding estimate of the measurement uncertainty is evaluated. This uncertainty estimate is stated when reporting test results to enable the user of the test report to assess the reliability of the result in accordance with the annex to this standard (Annex A). The measurement uncertainty is calculated in accordance with Joint Committee on Metrology Guides 100.
In principle, when testing, a subject wearing a respiratory protective device performs a series of exercises while surrounded by an atmosphere containing a known concentration of the test substance. During these exercises, the concentration of the test substance inside and outside the respiratory interface is measured and compared.
Three test substances are specified for test substance selection: a solid aerosol, a liquid aerosol and a gas. The general principle of the test is the same for all substances. The test substances used depend on the type of respiratory protective device being tested (selected according to the figures given in the standard). When sodium chloride is used as the test substance for type T respiratory interfaces (tight fit), Method 2A (impulse sampling) is used. When the choice of gas or aerosol is permitted, aerosol test methods are preferred. Sulfur hexafluoride is a greenhouse gas and is considered undesirable if avoided.
According to this standard, three test items are specified for inward leakage tests:
All three test materials are equally acceptable for determining inward leakage or total inward leakage, subject to the selection requirements in the standard. If the results from the porosity test of the materials indicate porosity, the respiratory protective device shall be tested using sulphur hexafluoride gas.
Unless otherwise specified in the performance standards, the test panel consists of 15 test subjects selected according to the following criteria:
Our organization has a strong staff that closely follows the developments in the world in the field of science and technology and constantly improves itself. Among the numerous test, measurement, analysis and evaluation studies provided for businesses in various sectors, there are also test services in accordance with the standard “ISO 16900-1 Respiratory protective devices - Test methods and test equipment - Part 1: Determination of inward leakage”.