The EN 50525 standard, which is a European standard, consists of the following sections under the main title "Electric cables - Low voltage energy cables with nominal voltages up to 450/750 V (U0/U)":
-ye-kadar-olan-alcak-gerilim-enerji-kablolari.jpg)
The EN 50525-1 standard describes the general requirements for rigid and flexible power cables with rated voltages up to (inclusive) U0/U 450/750 V AC used in power installations and domestic and industrial devices and equipment. Test methods for checking compliance with these requirements are given in other parts of this standard.
EN 50525-2-11 standard applies to flexible cables with thermoplastic (PVC) insulation and PVC sheath. The cables have rated voltages U300/U up to (inclusive) 500/0 V. The cables are designed for connecting household appliances to a fixed supply. Circular cables and flat cables are included.
The EN 50525-2-12 standard applies to expandable ends with thermoplastic (PVC) insulation and PVC sheath. The cables have rated voltages U300/U up to (inclusive) 500/0 V. The cables are designed for connecting household appliances to a fixed supply. Circular cables and flat cables are included.
The EN 50525-2-21 standard applies to flexible cables insulated with a cross-linked elastomeric compound and coated with a cross-linked elastomeric compound or thermoplastic polyurethane. The cables have rated voltages U450/U up to (inclusive) 750/0 V. The cables are designed for a variety of applications where the device or equipment, including heavy industrial equipment, requires a flexible connection to the power supply.
The EN 50525-2-22 standard applies to cross-linked EPR insulated and textile braided flexible cables. The cables have a nominal voltage of U0/U 300/300 V. The cables are designed for connecting household appliances to the fixed supply where an extra flexible connection is required.
The EN 50525-2-31 standard applies to unsheathed single core cables insulated with thermoplastic (PVC) insulation. The cables have rated voltages U450/U up to (inclusive) 750/0 V. The cables are designed for fixed wiring applications.
The EN 50525-2-41 standard applies to unsheathed single-core cables insulated with halogen-free cross-linked compound and exhibiting low smoke and corrosive gas emissions when exposed to fire. Low smoke emission is checked according to the EN 61034-2 standard. Low corrosive gas emission is checked as part of the halogen-free testing. The cables have rated voltages U0/U up to (inclusive) 450/750 V.
EN 50525-2-42 standard applies to single core unsheathed cables with cross-linked elastomeric insulation. The cables have rated voltages U450/U up to (inclusive) 750/0 V.
EN 50525-2-51 standard applies to flexible cables with oil resistant polyvinyl chloride insulation and sheath. Screened and unshielded types are included. The cables have a nominal voltage U0/U 300/500 V. The cables are designed for interconnection of machine tools.
Standard EN 50525-2-71 applies to flexible flat tinsel flexible cables with thermoplastic (PVC) insulation. The cables have a nominal voltage of U0/U 300/300 V. The cables are designed for connecting small devices to fixed power supply.
The EN 50525-2-72 standard applies to straight split flexible cables with thermoplastic (PVC) insulation. The cables have a nominal voltage of U0/U 300/300 V. The cables are designed for indoor use as a direct supply connection to internal wiring or luminaires.
The EN 50525-2-81 standard applies to single-core, cross-linked elastomer-coated arc welding cables. The cables have a nominal voltage of U0/U 100/100 V. The cables are designed for connections between the welding power source and the electrode holder and workpiece. Two types of cables are included with Class D and Class E conductors, respectively.
The EN 50525-2-82 standard applies to cables with polychloroprene or other equivalent synthetic elastomer sheathed. The cables have rated voltages U300/U up to (inclusive) 500/0 V. The cables are designed for use as decorative chains and with special sockets.
EN 50525-2-83 standard applies to multi-core cables insulated and sheathed with heat resistant cross-linked silicone rubber. Types with or without a general textile weave and with or without tension-bearing elements are included. The cables have nominal voltages U0/U 300/500 V. The cables are designed for use in high temperature regions (for fixed installations with mechanical shielding or for flexible use under low mechanical stress).
The EN 50525-3-11 standard applies to flexible cables coated with an insulated and halogen-free thermoplastic compound and have low smoke and corrosive gas emissions when exposed to fire. Low smoke emission is controlled according to EN 61034-2 standard. Low corrosive gas emission is controlled as part of checking for halogen absence. The cables have rated voltages U300/U up to (inclusive) 500/0 V. The cables are designed for connecting household appliances to a fixed supply. Circular cables and flat cables are included.
The EN 50525-3-21 standard applies to flexible cables insulated and sheathed with a halogen-free cross-linked compound and have a low emission of smoke and corrosive gas when exposed to fire. Low corrosive gas emission is controlled as part of checking for halogen absence.
The EN 50525-3-31 standard applies to unsheathed single core cables insulated with a halogen-free thermoplastic compound and have low smoke and corrosive gas emissions when exposed to fire. Low smoke emission is controlled according to EN 61034-2 standard. Low corrosive gas emission is controlled as part of checking for halogen absence. The cables have rated voltages U450/U up to (inclusive) 750/0 V. The cables are designed for fixed wiring applications.
The EN 50525-3-41 standard applies to unsheathed single core cables insulated with a halogen-free cross-linked compound and have low smoke and corrosive gas emissions when exposed to fire. Low smoke emission is controlled according to EN 61034-2 standard. Low corrosive gas emission is controlled as part of checking for halogen absence. The cables are designed for fixed wiring applications.
Our organization, among the numerous test, measurement, analysis and evaluation studies it has given for businesses in various sectors, with its trained and expert staff and advanced technological equipment, within the scope of EN 50525 standard, low voltages up to 450/750 V (U0/U) It also provides testing services for voltage energy cables.