IEC 60947-2 Low Voltage Switchgear and Controller - Part 2: Circuit Breakers

IEC 60947-2 Low Voltage Switchgear and Controller - Part 2: Circuit Breakers

The IEC 60947-2 standard, published by the International Electrotechnical Commission (IEC), applies to circuit breakers whose main contacts are intended to be connected to circuits and whose rated voltage does not exceed 1000 Volts alternating current or 1500 Volts direct current. This standard also includes additional requirements for circuit breakers with integrated fuses. Circuit breakers with a rated voltage above 1000 Volts alternating current but not exceeding 1500 Volts alternating current are also tested according to this standard. This standard applies regardless of the rated current, construction method, or recommended application of the circuit breakers.

IEC 60947-2 Low Voltage Switchgear and Controller - Part 2: Circuit Breakers

The latest update of this standard includes some technical changes. Namely,

  • Tests for verification of selectivity given in Annex A
  • Critical load current tests circuit breakers for direct current
  • A new addition (Annex P) for circuit breakers for use in photovoltaic applications
  • A new addition (Annex R) for residual current circuit breakers with automatic reclosing functions

The requirements for circuit breakers with various features in the IEC 60947-2 standard are included in the following annexes:

  • Requirements for circuit breakers intended to provide earth leakage protection (Annex B)
  • Additional requirements for circuit breakers with electronic overcurrent protection (Annex F)
  • Additional requirements for circuit breakers for information technology systems (Annex H)
  • Requirements and test methods for electromagnetic compatibility of circuit breakers (Annex J)
  • Requirements for circuit breakers that do not meet the overcurrent protection requirements (Annex L)
  • Requirements for modular residual current devices (without integrated current breaking device) (Annex M)
  • Requirements and test methods for electromagnetic compatibility of circuit-breaker aids (Annex N)
  • Requirements and test methods for DC circuit breakers for use in photovoltaic applications (Annex P)
  • Requirements and test methods for circuit breakers with residual current protection with automatic reclosure functions (Annex R)

Among the numerous test, measurement, analysis and evaluation studies it provides for businesses in various sectors, our organization also provides testing services for low voltage switchgear and circuit breakers with control mechanism, within the scope of IEC 60947-2 standard, with its trained and expert staff and advanced technological equipment.