The “ISO 17299 Textiles - Determination of Deodorant Properties” standard, developed by the International Organization for Standardization (ISO) , consists of the following sub-sections published under the same title:

In principle, the concentration of gaseous odor component chemicals in the sampled containers (A) and unsampled containers (B) is measured using the specified instruments after the specified contact time. The reduction rate is determined from the chemical concentration with and without the sample. The test should be conducted either with the odor chemical alone or with mixed odor component chemicals, as described in each section of ISO 17299.
The test environment must be maintained at 20 degrees Celsius and 65 percent relative humidity, according to the ISO 139 standard. Samples are kept under the same conditions for at least 24 hours. For this test, a temperature of 23 degrees Celsius and 50 percent relative humidity, according to the ISO 139 standard, can be used, and the conditions used are then recorded in the test report.
The test procedure is described in other parts of this standard. In all parts, the concentrations of the test gas without and with the sample are shown as B and A, respectively.
In principle, the concentration of gaseous odor component chemicals in containers with or without a test sample after a specified contact time is measured using detector tubes. The percentage odor reduction of the chemical concentration is calculated from the concentration data with and without the sample. Each chemical must be tested separately.
Testing for each odor component chemical is performed separately. Each odor component chemical is prepared immediately prior to testing. Other gas preparation methods, such as using a standard gas generator (e.g., a parmearator or cylinder), may also be used.
The test environment is maintained at 20 degrees Celsius and 65 percent relative humidity in accordance with ISO 139. The dimensions and masses of the samples are shown in the table provided in the standard. The number of test samples for a test is three. For multi-layered products, the edge and the untreated layer (or the unrelated layer) can be covered with aluminum foil to prevent contact with odorous gas, or the sample can be folded in half with the untreated layer inside. The samples are conditioned under the conditions used for the test for at least 24 hours.
In principle, the concentration of gaseous odorant chemicals in containers with or without a test sample is measured by gas chromatography (GC) after a specified contact time. The rate of decrease in the concentration of odorants in the container is calculated from the concentration data with and without the sample.
The test environment used in this test is 20 degrees room temperature and 65 percent relative humidity in accordance with the ISO 139 standard.
This standard defines two preparation methods: method A and method B. One method is selected with the approval of the relevant parties. For textile products, the sample size or mass is indicated in the table provided in the standard. For multi-layered products, the edge and the untreated layer (or non-relevant layer) can be covered with aluminum sheets to prevent contact with the odor medium, or in method A, the product can be folded in half with the non-relevant layer inside.
In principle, the concentration of a gaseous odorant in a container with or without a textile sample is measured using instrumentation after a specified time. The rate of decrease in the gaseous odorant concentration is calculated from the difference between the average concentration data obtained between the container with and without the sample. Testing should be performed separately for each chemical.
For textile products, the sample size or mass is shown in the table provided in the standard. For multilayer products, the edge and the untreated layer (or untargeted layer) may be covered with an aluminum sheet, or the test sample may be folded in half with the untreated layers facing inward to prevent the untreated layers from coming into contact with the odorous atmosphere. The sample is conditioned as specified in ISO 17299-1.
In principle, semi-unpleasant odorous gases are placed in plastic bags with or without a test sample. After a 2-hour reaction time, the odor unit concentration of the remaining gases is obtained using an odor tester with 10 metal oxide semiconductor sensors. The rate of decrease in odor chemical concentration is calculated from the odor unit concentration with and without the sample.
One or both methods are selected with the approval of the relevant parties. Examples of test conditions are included in the standard appendix (Annex B).
Our organization, which has been supporting businesses across all sectors for years through a wide range of testing, measurement, analysis, and evaluation activities, has a strong team of employees who closely follow global developments in science and technology and are constantly improving themselves. In this context, we also provide testing services in accordance with the ISO 17299 Textiles - Determination of Deodorant Properties standard.