The basic standard “EN ISO 11092 Textiles - Physiological effects - Measurement of thermal and water vapour resistance under steady-state conditions (hot plate test with perspiration protection)”, developed by the British Standards Institution (BSI) and published by the International Standards Organisation (ISO), describes a procedure for measuring thermal resistance and water vapour resistance under steady-state conditions for use in clothing, duvets, sleeping bags, upholstery and textile-like products, including multi-layer assemblies such as fabrics, films, coatings, foams and leather.
.jpg)
The application of this measurement technique is limited by the maximum thermal resistance and water vapour resistance, which depend on the dimensions and construction of the device used (for example, the minimum characteristics of the equipment specified in this standard are 2 m2 K/W and 700 m2 Pa/W, respectively).
The test conditions used in this international standard are not intended to represent specific comfort situations, and performance characteristics related to physiological comfort are not specified.
For the purposes of this standard, the following terms and definitions apply:
When testing, in principle, the sample to be tested is placed on an electrically heated plate with conditioned air channels to flow parallel and crosswise to its upper surface as specified in this standard.
To determine thermal resistance, the heat flux through the test sample is measured after steady-state conditions are reached.
This technique allows the thermal resistance of a material to be determined by subtracting the thermal resistance of the boundary air layer above the surface of the test device from the thermal resistance of a test specimen and the boundary air layer measured under the same conditions.
To determine the water vapor resistance, an electrically heated porous plate is covered with a membrane that is permeable to water vapor but impermeable to liquid water. Water fed to the heated plate evaporates and passes through the membrane as vapor, so that liquid water does not contact the test sample. When the test sample is placed on the membrane, the heat flux required to maintain a constant temperature in the plate is a measure of the rate of evaporation of water, and from this the water vapor resistance of the test sample is determined.
The measuring unit with temperature and water supply control consists of a metal plate with a thickness of about 3 mm and a minimum area of 0,04 m2 (for example, a square with a length of 200 mm on each side) fixed to a conductive metal block containing an electric heating element. For measuring water vapor resistance, the metal plate must be porous. This device is surrounded by a thermal guard located in an opening in a measuring table.
Among the numerous tests, measurements, analyses and evaluation studies that our organization has carried out for businesses in various sectors, our organization also provides testing services defined in the standard “EN ISO 11092 Textiles - Physiological effects - Measurement of thermal and water vapor resistance under steady-state conditions (hot plate test with sweat protection)” with its trained and expert staff and advanced technological equipment.