The ISO 8301 Thermal insulation - Determination of steady-state heat resistance and related properties - Heat flow metering device standard, published by the International Organization for Standardization (ISO), describes the use of the heat flow metering method to measure steady-state heat transfer through flat plate samples and to calculate heat transfer properties. This is a secondary or relative method in which the ratio of the thermal resistance of the sample or samples to the thermal resistance of a standard sample or samples is measured.

ISO 8301 Thermal Insulation - Determination of Steady-State Thermal Resistance and Related Properties - Heat Flow Meter

Reports conforming to this standard test method should refer to samples with a thermal resistance greater than 0,1 m²·K/W, provided that the thickness limits given herein are not exceeded. The samples must:

  • If it meets the requirements specified in Clause 1.8.1, the obtained properties should be defined as the thermal conductivity and thermal resistance of the sample.
  • If it meets the requirements specified in Clause 1.8.2, the obtained properties should be defined as the average thermal conductivity of the evaluated sample.
  • If it meets the requirements specified in Clause 1.8.3, the resulting property can be defined as the thermal conductivity or permeability of the material being evaluated.

The thermal conductivity properties of a material sample can vary for several reasons. These variations depend on the composition of the material or samples.

  • It can be affected by humidity or other factors.
  • It may change over time.
  • It may vary depending on the average temperature.
  • It may depend on previous thermal history.

Therefore, the selection of a typical heat transfer property value representing a material in a particular application must be based on consideration of these factors and may not necessarily be applicable to all service conditions without modification.

For example, this method dictates that heat transfer properties should be achieved on dried samples, but these conditions may not be met in service. More fundamentally, heat transfer properties depend on variables such as mean temperature and temperature difference. This dependence must be measured or tested under typical operating conditions.

Sufficient information is needed for heat transfer properties to be considered representative of a material. A material's heat transfer property can only be determined by a single measurement if the sample is a typical example of the material and the samples are also typical examples of the sample. The sample selection procedure should normally be specified in the material specification. Sample selection from a sample may be partially specified in the material specification. Since sampling is outside the scope of this method, when the issue is not addressed in a material specification, the relevant standards should be consulted.

The ISO 8301 standard includes a heat flow meter method for measuring the steady-state thermal properties of flat sheet samples, particularly those used as insulation materials. This is a secondary (relative) measurement technique: it compares the heat transfer through the test sample to the heat transfer through a calibrated reference (standard) sample under controlled conditions.

The main applications are:

  • To determine the thermal resistance (R-value) and thermal conductivity of the samples.
  • Calculating the average thermal conductivity (often referred to as apparent or effective thermal conductivity) under specific conditions.
  • To evaluate insulation materials used in building construction, industrial processes, cooling, and energy-efficient products.

This method is particularly suitable for materials with low conductivity, such as foams, fibrous insulations (e.g., mineral wool, glass fiber), cellular plastics, and other porous or low-density insulation materials, where heat transfer involves conduction, radiation, and sometimes small amounts of convection or gas effects.

It is important to note that the measured thermal conductivity is not always an intrinsic property of the material; it is usually a transfer factor that can depend on sample thickness, temperature difference, mean temperature, moisture content, and surface emissivity (due to radiation effects). This standard emphasizes careful reporting of results to prevent misinterpretation.

The equipment used in these tests consists of the following:

  • Two temperature-controlled plates (hot and cold) surrounding the sample.
  • One or more heat flux transducers (heat flow meters) are placed between the plates and the sample to directly measure the rate of heat flow through the sample.
  • Temperature sensors are used to measure temperature differences across the sample thickness.
  • Under steady-state conditions (constant heat flow and temperatures), thermal resistance is calculated according to the formula given in the standard: thermal resistance (m²·K/W) = Measurement area (m²) x Temperature difference across the sample (K) / Heat flow rate through the measurement area (W). Thermal conductivity can then be obtained as: Sample thickness / Thermal resistance.

This method relies on calibration with reference materials that have known thermal resistance to account for device-specific factors.

The basic requirements and conditions are as follows:

  • Sample shape: Flat plates with parallel sides.
  • Applicable thermal resistance: Typically at least 0,1 m²·K/W (to ensure sufficient accuracy).
  • Thickness limits: Specified to avoid edge effects and ensure one-dimensional heat flow.
  • Temperature range: Generally moderate (e.g., from room temperature to approximately 100-200 degrees Celsius depending on the device), the average test temperature is controlled.
  • Special considerations: This standard addresses radiation heat transfer, edge losses, contact resistance, humidity effects, and device design to minimize errors.
  • Calibration: The instrument must be calibrated using certified reference samples (typically associated with primary methods such as protected hot plate according to ISO 8302 standard).

This method relates to the following standards:

  • ISO 8302 standard: Uses a protected hot plate device (primary method, generally more accurate for homogeneous materials).
  • The ASTM C518 standard is very similar to the ISO 8301 standard; the heat flow measurement method is practically compatible between the two, and many devices conform to both.

The ISO 8301 standard is actively used worldwide in laboratories, certification bodies, and quality control for insulation products. This standard plays a critical role in providing consistent, reliable, and comparable thermal performance data for insulation materials. This is essential for energy efficiency regulations, building codes, product labeling (e.g., U-values ​​or lambda values), and sustainable construction research.

In conclusion, the main objectives of the ISO 8301 standard are as follows:

  • Measuring thermal conductivity
  • Measuring heat resistance
  • To evaluate the thermal insulation performance of materials.
  • To provide standardized and repeatable measurement conditions.

For many years, our organization, with its competent and experienced staff, has been understanding the needs of its clients, providing the advanced testing services they require, and assisting them in the establishment, implementation, and improvement of management systems. Within this framework, we also provide testing services compliant with the ISO 8301 standard.