EUROLAB With its expert team and state-of-the-art laboratories, it offers reliable and unbiased results in automotive tests, as in all other tests.

LV-124 Tests for Automotive

LV-124 K-01 High/low temperature storage according to EN 60068-2-14 

  • Test time and test temperature: 24 cycles for 2 hours each (Tmin: consists of 40 hours storage at -12°C and 12 hours storage at Tmax: +85°C);
  • Gradient: 1K/Min
  • Working mode: Ia
  • Parameter testing (large, tbd) is then performed
  • Number of DUTs: 9

LV-124 K-01 High/low temperature storage according to EN 60068-2-14 

  • Test temperature: temperature profile according to Figure 27;
  • Temperature change per rise: 5°C;
  • Holding time: from 5 to 10 minutes;
  • next parameter Test time 48 hours;
  • Test temperature: Tmin: -55°C (-40°C and additional -15°C depending on operating mode), Tmax: +85°C;
  • Working mode: II.c
  • During parameter testing (functional testing required)
  • Otherwise operating mode II.a
  • Number of DUTs: 9

LV-124 K-03 Low temperature operation according to EN 60068-2-1

  • Test duration 48 hours;
  • Test temperature: Tmin: -55°C (-40°C and additional -15°C depending on operating mode)
  • Operating mode: Intermittent, 12 h II.a and 12 h II.c
  • -Parameter testing (small, tbd) is then performed Number of DUTs: 6

LV-124 K-05 Temperature shock (component) according to EN 60068-2-14 Na

  • Lower temperature: Tmin -40°C;
  • Upper temperature: Tmax: +85° C;
  • Waiting time at upper/lower temperature: assumption 20 min (15 min + 5 min);
  • Transfer time: < 30s;
  • Number of cycles: 100
  • Working mode: Ib
  • -Parameter testing (large, tbd) is done later
  • Number of DUTs: 6

LV-124 K-08 Humid heat, cyclic according to EN 60068-2-30

  • Test variant: Variant 1; Tmax: 55°C;
  • Number of cycles: 6;
  • Duration: 144 h
  • Parameter test (functional test required)
  • Working mode: II.a
  • -Parameter testing (large, tbd) is done later
  • Number of DUTs: 6

LV-124 K-09 Humid heat, cyclic (frosty) according to EN 60068-2-38

  • Duration: 240 hours;
  • Number of cycles: 10;
  • Test cycle sequence: The first five cycles must contain a cold phase and the remaining cycles must be performed without a cold phase.
  • Operating mode: Intermittent 40 min II.a and 10 min II.c
  • -Parameter testing (large) is then performed
  • Number of DUTs: 6

LV-124 K-10 Water Protection

LV-124 K-14 Constant damp heat – intensity 2 according to EN 60068-2-78

  • Temperature: 65°C;
  • rel. humidity: 93% ;
  • Duration: 751 h
  • Intermittent operation, 47-hour operating mode II.a and 1-hour operating mode II.c
  • -Parameter testing (large, tbd) is done later
  • Number of DUTs: 6

LV-124 K-16 Thermal Shock

LV-124 K-18 Noxious gas test with flowing mixed gas according to EN 60068-2-60

  • Method: 4;
  • Temperature: 25 °C;
  • rel. humidity: 75% ;
  • Duration: 21 days
  • Working mode: Ib
  • Parameter testing (large, tbd) is then performed
  • Number of DUTs: 6

LV-124 Chemical resistance compared to LV124

Number of chemicals: 8
– Multiple uses of a DUT for more than one chemical are permitted in coordination with the recipient.

As specified in the Component Performance Specifications.

Substances:
1) Windshield washer fluid (2 hours, 23°C),
2) Interior cleaner / cockpit spray (2 hours, 23°C),
3) Glass cleaner (2 hours, 23°C),
4) Denatured Alcohol (10 min, 23°C),
5) Contact Spray (22 hours, 85°C),
6) Sweating (sweat) (22 hours, 23°C),
7) Cosmetics, eg creams (22 hours, 23°C),
8) Snack containing caffeine and sugar (22 hours, 23°C),

One (1) DUT per chemical

LV-124 L-02 Life test – high temperature endurance test

  • Test duration : 1536 h;
  • Test temperature: Tmax: +85° C
  • Operating mode: Intermittent, 47 h II.c and 1 h II.a,
  • – The parameter test (large) will be done later.
  • Number of DUTs: 6

LV-124 L-03 Life test – temperature cycle test

  • Test duration: 840 hours
  • Test temperature: Tmin: -55°C (-40°C and additional -15°C depending on operating mode); Tmax: +85°C;
  • Temperature gradient: 4 °C/min
  • – Holding time at Tmin and Tmax: 15 minutes after the component reaches the condition at which it maintains the temperature
  • Operating mode: interrupt II.a and II.c
  • – Parameter test (large, tbd) performed later
  • Number of DUTs: 6