LV-124 Tests for Automotive
EUROLAB With its expert team and state-of-the-art laboratories, it offers reliable and unbiased results in automotive tests, as in all other tests.

LV-124 K-01 High/low temperature storage according to EN 60068-2-14
- Test time and test temperature: 24 cycles for 2 hours each (Tmin: consists of 40 hours storage at -12°C and 12 hours storage at Tmax: +85°C);
- Gradient: 1K/Min
- Working mode: Ia
- Parameter testing (large, tbd) is then performed
- Number of DUTs: 9
LV-124 K-01 High/low temperature storage according to EN 60068-2-14
- Test temperature: temperature profile according to Figure 27;
- Temperature change per rise: 5°C;
- Holding time: from 5 to 10 minutes;
- next parameter Test time 48 hours;
- Test temperature: Tmin: -55°C (-40°C and additional -15°C depending on operating mode), Tmax: +85°C;
- Working mode: II.c
- During parameter testing (functional testing required)
- Otherwise operating mode II.a
- Number of DUTs: 9
LV-124 K-03 Low temperature operation according to EN 60068-2-1
- Test duration 48 hours;
- Test temperature: Tmin: -55°C (-40°C and additional -15°C depending on operating mode)
- Operating mode: Intermittent, 12 h II.a and 12 h II.c
- -Parameter testing (small, tbd) is then performed Number of DUTs: 6
LV-124 K-05 Temperature shock (component) according to EN 60068-2-14 Na
- Lower temperature: Tmin -40°C;
- Upper temperature: Tmax: +85° C;
- Waiting time at upper/lower temperature: assumption 20 min (15 min + 5 min);
- Transfer time: < 30s;
- Number of cycles: 100
- Working mode: Ib
- -Parameter testing (large, tbd) is done later
- Number of DUTs: 6
LV-124 K-08 Humid heat, cyclic according to EN 60068-2-30
- Test variant: Variant 1; Tmax: 55°C;
- Number of cycles: 6;
- Duration: 144 h
- Parameter test (functional test required)
- Working mode: II.a
- -Parameter testing (large, tbd) is done later
- Number of DUTs: 6
LV-124 K-09 Humid heat, cyclic (frosty) according to EN 60068-2-38
- Duration: 240 hours;
- Number of cycles: 10;
- Test cycle sequence: The first five cycles must contain a cold phase and the remaining cycles must be performed without a cold phase.
- Operating mode: Intermittent 40 min II.a and 10 min II.c
- -Parameter testing (large) is then performed
- Number of DUTs: 6
LV-124 K-10 Water Protection
LV-124 K-14 Constant damp heat – intensity 2 according to EN 60068-2-78
- Temperature: 65°C;
- rel. humidity: 93% ;
- Duration: 751 h
- Intermittent operation, 47-hour operating mode II.a and 1-hour operating mode II.c
- -Parameter testing (large, tbd) is done later
- Number of DUTs: 6
LV-124 K-16 Thermal Shock
LV-124 K-18 Noxious gas test with flowing mixed gas according to EN 60068-2-60
- Method: 4;
- Temperature: 25 °C;
- rel. humidity: 75% ;
- Duration: 21 days
- Working mode: Ib
- Parameter testing (large, tbd) is then performed
- Number of DUTs: 6
LV-124 Chemical resistance compared to LV124
Number of chemicals: 8
– Multiple uses of a DUT for more than one chemical are permitted in coordination with the recipient.
As specified in the Component Performance Specifications.
Substances:
1) Windshield washer fluid (2 hours, 23°C),
2) Interior cleaner / cockpit spray (2 hours, 23°C),
3) Glass cleaner (2 hours, 23°C),
4) Denatured Alcohol (10 min, 23°C),
5) Contact Spray (22 hours, 85°C),
6) Sweating (sweat) (22 hours, 23°C),
7) Cosmetics, eg creams (22 hours, 23°C),
8) Snack containing caffeine and sugar (22 hours, 23°C),
One (1) DUT per chemical
LV-124 L-02 Life test – high temperature endurance test
- Test duration : 1536 h;
- Test temperature: Tmax: +85° C
- Operating mode: Intermittent, 47 h II.c and 1 h II.a,
- – The parameter test (large) will be done later.
- Number of DUTs: 6
LV-124 L-03 Life test – temperature cycle test
- Test duration: 840 hours
- Test temperature: Tmin: -55°C (-40°C and additional -15°C depending on operating mode); Tmax: +85°C;
- Temperature gradient: 4 °C/min
- – Holding time at Tmin and Tmax: 15 minutes after the component reaches the condition at which it maintains the temperature
- Operating mode: interrupt II.a and II.c
- – Parameter test (large, tbd) performed later
- Number of DUTs: 6