The standard "VDA 230-223 Plastic covers for automotive interiors - Testing of amine compatibility" published by the German Association of the Automotive Industry (VDA) describes a method for testing the compatibility of plastic cover products made of polyvinyl chloride (PVC). This method simulates the color and odor change of PVC plastic covers under the influence of amines that can be released from other materials (e.g. polyurethane foams). This standard acts together with the standard "VDA 270 Determination of odor behavior of materials used in vehicle interiors".

The materials are stored in a closed system at high temperature and in the presence of amine. Temperature, amine amount and test geometry are strictly defined. Color and odor change after storage are evaluated.
Depending on the application, this procedure is performed using one of the following test methods:
For the purposes of this standard, amine compatibility means that the PVC material does not change colour or deteriorate due to the action of amines at high temperatures.
Equipment and chemicals used in these tests include:
Test conditions for Method A, Method B and Method C are shown in the table provided in the standard.
In preparing the test, 5 of the samples are placed against the glass with their backs (the side not visible when placed) over the top edge of the 100 ml beaker. This leaves approximately 50 mm of the sample length inside the glass and the remaining sample length hanging down the outer glass wall. The samples are then fixed with tape at a height of 15 mm from the bottom of the beaker. In the case of rigid materials, these can be temporarily fixed with an inert clamp to facilitate the attachment of the tape. In such cases, it is also useful to make lateral cuts at the point where the samples are inverted.
Then the watch glass is placed in the center of the bottom of the 150 ml beaker, then the amount of amine catalyst determined according to the process is weighed into the watch glass using a pipette and a balance. After the weighing process is completed, the 150 ml beaker is immediately placed in the center of the special desiccator. The slide is placed in the center of the beaker slide. Then, the beaker containing 5 samples is placed in the center of the slide and the desiccator is closed. Ground joint grease should be used to ensure the sealing of the desiccator. The lid is fixed with a metal quick-release fastener.
The desiccator is then placed in a circulating air drying cabinet for 24 hours at the temperature specified for the process. After removing the desiccant from the drying cabinet, it is left to cool at room temperature for a maximum of 30 minutes. The desiccator is then opened under a fume hood and the test samples are immediately removed. Even if an odor test is not required, five samples should always be exposed to the amine. Different materials should never be tested simultaneously in a desiccator.
Our organization, which has been trying to support businesses from every sector with its wide range of testing, measurement, analysis and evaluation studies for years, has a strong staff that closely follows the developments in the world in the field of science and technology and constantly improves itself. In this context, testing services in accordance with the standard "VDA 230-223 Plastic covers for automotive interiors - Testing of amine compatibility" are also provided to businesses.